STU 3 Candidate

This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Obs-uslab-example5.ttl

Raw Turtle, JSON-LD

USLab Quantitative Observation Profile Example: Blood Lead

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/owl#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xs: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir//Observation/obs-uslab-example5> a fhir:Observation;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "obs-uslab-example5"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ]
  ];
  fhir:DomainResource.extension [
     fhir:index 0;
     fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/uslab-observationkind" ];
     fhir:Extension.valueCode [ fhir:value "result" ]
  ];
  fhir:Observation.identifier [
     fhir:index 0;
     fhir:Identifier.use [ fhir:value "official" ];
     fhir:Identifier.type [
       fhir:CodeableConcept.text [ fhir:value "lab test result ID" ]     ];
     fhir:Identifier.system [ fhir:value "http://lis.acmelabs.org/identifiers/labtestresult" ];
     fhir:Identifier.value [ fhir:value "1234" ]
  ];
  fhir:Observation.status [ fhir:value "final"];
  fhir:Observation.code [
     a loinc:5671-3;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a loinc:5671-3;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "5671-3" ];
       fhir:Coding.display [ fhir:value "Lead [Mass/volume] in Blood" ]     ];
     fhir:CodeableConcept.coding [
       fhir:index 1;
       fhir:Coding.system [ fhir:value "urn:oid:2.16.840.1.113883.3.72.5.24" ];
       fhir:Coding.code [ fhir:value "BLDLD" ];
       fhir:Coding.display [ fhir:value "Blood Lead" ]     ];
     fhir:CodeableConcept.text [ fhir:value "Blood Lead" ]
  ];
  fhir:Observation.subjectReference [
     fhir:reference <http://hl7.org/fhir/Patient/patient-uslab-example1>;
     fhir:Reference.reference [ fhir:value "Patient/patient-uslab-example1" ];
     fhir:Reference.display [ fhir:value "Todd Lerr" ]
  ];
  fhir:Observation.effectiveDateTime [ fhir:value "2014-12-05"^^xs:date];
  fhir:Observation.issued [ fhir:value "2014-12-06T15:42:15-08:00"^^xs:dateTime];
  fhir:Observation.performerReference [
     fhir:index 0;
     fhir:reference <http://hl7.org/fhir/Practitioner/pract-uslab-example1>;
     fhir:Reference.reference [ fhir:value "Practitioner/pract-uslab-example1" ];
     fhir:Reference.display [ fhir:value "Dr Leonard T Bloodraw Jr" ]
  ];
  fhir:Observation.valueQuantity [
     fhir:Quantity.value [ fhir:value "65"^^xs:decimal ];
     fhir:Quantity.unit [ fhir:value "microgram per deciliter" ];
     fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
     fhir:Quantity.code [ fhir:value "ug/dL" ]
  ];
  fhir:Observation.interpretation [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0078" ];
       fhir:Coding.code [ fhir:value "H" ]     ]
  ];
  fhir:Observation.specimen [
     fhir:reference <http://hl7.org/fhir/Specimen/spec-uslab-example1>;
     fhir:Reference.reference [ fhir:value "Specimen/spec-uslab-example1" ];
     fhir:Reference.display [ fhir:value "Blood sample" ]
  ];
  fhir:Observation.referenceRange [
     fhir:index 0;
     fhir:Observation.referenceRange.high [
       fhir:Quantity.value [ fhir:value "5.0"^^xs:decimal ];
       fhir:Quantity.unit [ fhir:value "microgram per deciliter" ];
       fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
       fhir:Quantity.code [ fhir:value "ug/dL" ]     ]
  ].

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.